AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

Axoclamp 900A Buy NowDownload BrochureDownload Manual
       

Computer-Controlled High-Compliance Current Clamp and Voltage Clamp

MultiClamp 700BThe Axoclamp 900A is a complete microelectrode current-clamp and voltage-clamp amplifier, useful for a wide range of intracellular microelectrode recording techniques. Like it's predecessor, the Axoclamp-2B, the Axoclamp 900A has a wide range of functionality and has many enhancements that improve amplifier recording capability, make the amplifier easier to use, and help your experiments last longer.

The Axoclamp 900A has several modes of operation:

• I-Clamp: two independent bridge amplifiers for voltage measurements

• DCC: discontinuous current clamp for accurate voltage measurements, even when electrode resistance changes

• TEVC: high-compliance two-electrode voltage clamp for oocytes and mammalian cells

• dSEVC: discontinuous single-electrode voltage clamp for small cells with large currents

• HVIC: high-voltage current clamp for extracellular applications such as iontophoresis

Note that this amplifier does not have continuous single-electrode voltage clamp mode. However this mode is available in our patch-clamp amplifiers: the MultiClamp 700B and Axopatch 200B. Please see the amplifier comparison chart for more details on the features of our amplifiers.


Software Control

 

Instead of the usual front panel knobs and switches, the Axoclamp 900A is controlled by the Axoclamp 900A Commander, a program that runs on a Windows PC computer (see Requirements below) and communicates with the amplifier via a USB 2.0 interface. This control interface reports resistance, voltage, and current measurements and provides automation of Bridge Balance, Pipette Offset, and Pipette Capacitance Neutralization. In addition it has "smart" features that protect cells from potentially damaging signal oscillations and automate mode changes based on internal signal thresholds or externally-applied signals. Amplifier settings such as gain, filter frequency, recording mode and input/output scale factors are automatically telegraphed to the pCLAMP 10 data acquisition software via the USB connection.

Software Control

Optional SoftPanel

 
Although the Axoclamp 900A is a computer-controlled amplifier, the mouse and/or keyboard is not the only means of controlling the instrument. The optional SoftPanel was designed for those who prefer the more conventional feel to amplifier control of knobs and buttons. By way of a USB connection, the SoftPanel physically replicates all essential amplifier functions by acting as a hardware extension of the Axoclamp 900A Commander software. SoftPanel knobs replicate continuous mouse controls ("gliders"), while buttons replicate single-click mouse controls. SoftPanel

More Information

The Axoclamp 900A* main unit comes standard with:

• One Remote BUZZ Box: works for both channels
• One Clamp-1U model cell
• Two HL-U electrode holders
•  One Axoclamp 900A Commander software CD
• Two USB cables
• Two headstage baseplates
• Theory and Operation User Guide (printed)

* Two HS-9A headstages (e.g., HS-9A x0.1, HS-9A x1 or HS-9A x10) must be ordered with the Axoclamp 900A.

Requirements

Computer Control
The Axoclamp 900A Commander program runs on Windows XP/2000 operating systems.

Two USB 2.0 ports are required to connect the computer to the Axoclamp 900A: one for amplifier control and one for Monitor signal display on the computer screen for discontinuous modes. An additional USB port is required if the optional SoftPanel is used to control the amplifier.

Experimental Control and Data Acquisition**
Although the Axoclamp 900A is controlled by a software interface, it remains a conventional analog input/output amplifier. Thus, it requires a separate system for controlling stimulus protocols and recording the output, such as a digitizer and data acquisition software. The Digidata 1550 digitizer and pCLAMP 10 data acquisition and analysis software from Molecular Devices, work together to provide the most complete, integrated solution.

** Automatic telegraphing of the Axoclamp 900A amplifier requires pCLAMP 10 software and a Digidata 1550 or Digidata 1320 series digitizer.

Excellent Comprehensive Manual
We also provide a detailed User Guide that serves as a handbook of procedures for microelectrode users. Tutorials written by Axon Instruments staff and scientific consultants provide a useful guide to the operation of the instrument and are informative references for several electrophysiological techniques.

Buy NowDownload Brochure Download Manual