AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

DS3 Stimulator Buy NowDownload Brochure
       

DS3 Stimulator
Digitimer DS3 Isolated Constant Current Stimulator

Brief pulses of electricity are used in various biomedical research applications as a stimulus to excite nerve or muscle fibers. Several factors need to be considered when choosing the right stimulator.

The DS3 provides a precise Constant Current stimulus (up to 32mA) controllable in Pulse Duration and Amplitude and as with the DS2A this output comes from self-contained batteries. 

The DS3 also features a "clamp" or discharge circuit which discharges the output between stimuli, preventing a charge build up on the preparation.  In other constant current devices this charge build up can lead to a loss of stimulus.  The DS3 can be triggered by an external device such as our new DG2A Train/Delay Generator.  

NOTE: This stimulator is NOT approved for use on human subjects.


Constant Current Stimulator

• Four current ranges allow precise control of output between 2µA and 32mA.
•  Output discharge (Clamp) circuit prevents capacitance build-up during stimulus trains, which is important to prevent stimulus loss.
• 90v compliance provided.

DS3 Stimulator

Featuring

• Accurate and reproducible stimulus characteristics.
• Switchable polarity, variable output and duration ranges (20µs to 2s).
• External pulse duration control through the BNC trigger input.
• A single-shot button, which operates irrespective of trigger inputs.
•Cases manufactured from insulating material may be rack mounted using an optional mounting frame (Model D121-11) available from Digitimer Ltd.