AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

Products: Amplifiers and Stimulators Overview Download Brochure
 
 
Pico 2 Amp & Digitizer
Pico 2 Amp & DigitizerBrownlee Amplifiers
Pico, a full-featured, low-noise patch clamp amplifier with an integrated digitizer and headstage. Pico is ideally suited for whole cell (Vclamp and Iclamp) and single-channel (patch, planar lipid bilayer, and synthetic nanopore) recording, as well as cellular electrochemistry. Pico measures just 5.6" x 2.5" x 0.7" (14.2cm x 6.3cm x 1.8cm) and consumes less than 1 watt of power.
Learn More
 
 
Brownlee Amplifiers
Brownlee Amplifiers
Brownlee's quiet electrophysiology amplifiers have four channels of a high gain/low noise amplification, lowpass filter and output offset control with a memory function for each channel. The Brownlee Model 440 adds an 8-pole Bessel lowpass filter, auto-zeroing, a line-notch filter, highpass filter, multiple memories per channel, and a digital voltmeter. A wide bandwidth of over 500 kHz insures smooth recordings.
Learn More
 
 
NeuroLog System
NeuroLog System
The NeuroLog System is a compact, versatile, modular instrument for a variety of research: intracellular, extracellular, transducer & multi-channel isolated amplification; pulse generation & electrical stimulation; and signal processing & conditioning. One NeuroLog can be used to monitor several parameters of interest simultaneously. See our list of interchangeable NeuroLog modules.
Learn More
 
 
Hum Bug Noise Eliminator
Hum Bug Noise Eliminator
The Hum Bug is a device for canceling electrical interference in real-time, avoiding all of the traditional problems associated with notch filters like phase delays, amplitude errors, DC shifts or waveform distortion. The Hum Bug constructs a replica of noise present on the input signal and continuously subtracts it from the signal as it passes through the instrument, even when noise characteristics evolve over time.
Learn More
 
 
DS2A Voltage Stimulator
DS2A Voltage Stimulator
The DS2A provides a precise constant voltage stimulus (up to 100V) controllable in pulse duration and amplitude from self-contained batteries, making it ideally suited to electrophysiological recording in small preparations or cells where low noise is required.
Learn More
 
 
DS3 Current Stimulator
DS3 Current Stimulator
The DS3 provides a precise constant current stimulus (up to 32mA) controllable in pulse duration and amplitude from self-contained batteries like the DS2A. The DS3 also features a "clamp" or discharge circuit which discharges the output between stimuli, preventing a charge build up on the preparation which can lead to a loss of stimulus in other constant current devices.
Learn More
 
 
DS4 Bi-phasic Stimulus Isolator
DS4 Bi-phasic Stimulus Isolator
The DS4 takes an analogue voltage waveform defined within your own data acquisition/ control system and converts it into an isolated constant current stimulus. The DS4 will accept several input voltage ranges and produces four output range.. It also features a GATE input, so that several DS4 units can be controlled by a single analogue waveform, but enabled individually via this GATE input.
Learn More
 
 
DG2A Train Delay Generator
DG2A Train Delay Generator
The DG2A is a compact, free-standing, battery powered instrument which can be used to generate trigger pulses required for repetitive stimulation. Also featuring DELAY controls, it is useful for determining nerve or axonal Effective Refractory Period (ERP) through the production of a delayed second pulse. It is especially useful as a frequency generator for use with our DS2A and DS3 isolated stimulators.
Learn More
 
 
Table-top Equipment Rack
Table-top Equipment Rack
Table-Top Equipment Rack features standard 19” rack panel width mounting, rack mounting on E.I.A. universal spacing (5/8 - 5/8 - 1/2 inch), round hole punched for 10-32 clip nuts (included), a choice of two heights, 21" (12U) or 28" (16U) and more.
Learn More
 
 
Floor-standing Equipment Rack
Floor-standing Equipment Rack
Floor-standing Equipment Rack features standard 19” panel width (21.34” overall), usable depth of 16.5" without doors, 16" with doors (17.5" overall), knockdown rack unit is shipped in a flat pack container for handling ease & protection and more.
Learn More
 
 
Top Home Credits Privacy Terms Copyright

©2006-2016 AutoMate Scientific, Inc.