AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

MED64 Software - Evoked Potential Measurement Package Download Brochure
       
 

MED64 Software – Evoked Potential Measurement Package

For Recording and analysis of fEPSPs / LTP / LTD

Evoked Potential Measurement Package
View  Larger Image
Control panel for acquisition / stimulation parameters


Acquisition

• Evoked local field potentials (e.g. fEPSPs) on all 64 channels can be recorded in response to customizable user-defined stimulation parameters.

• Parameters for acquisition and stimulation including stimulus current amplitude and wave forms are designed easily with simple control panel.

• Users can design and apply complex stimulation sequences independently for each stimulator. Templates are included for delivery of repetitive (e.g. theta) stimuli.


Analysis

• Analysis of amplitude, slope and area parameters can be performed automatically during or after acquisition, and graphed independently for each channel. An arbitrary number of measures can be enabled, limited only by the processing power of your PC.

• Online and offline measures are also available for paired-pulse paradigms.

• Input / Output curve can be made with automatic increments for stimulus current.

• Averages and standard deviations for measurements can be automatically computed for all channels and graphed for user-defined “phases” of an experiment. This allows for easy construction of dose-response curves.

Evoked Potential Measurement Package
View  Larger Image
fEPSP analysis: [Left] extracted evoked signal [Right] Time course of measured 1) Amplitude Minimum (red), 2) Slope 10-40% (blue), and 3) Time from Minimum to Half-Minimum (yellow)

Evoked Potential Measurement Package
View  Larger Image
Paired Pulse Analysis: [Left] extracted evoked signal. [Right] Time course of measured Amplitude Minimum (red), and Slope 10-40% (blue) for the first and second pulse are shown. The bottom charts (yellow) show the paired pulse ratio for the Amplitude Minimum. The left chart shows the percent change in the second pulse with respect to the first pulse while the right chart shows the percent change in the first pulse with respect to the second pulse.


Available measurement protocols

• Amplitude (Minimum, Maximum, Peak to Peak)

• Slope (10-90%, 10-40%, Linear fit)

• Absolute Area

• Area Pop Spike

• Paired-pulse Ratio for above protocols

• Time of Amplitude Minimum (or Maximum)

• Time of Amplitude Minimum (or Max) to Minimum (or Max)

• Time from Minimum (Max) to Half-minimum (max)


Data Output

• Raw data can be exported in binary or ASCII text file (csv) format.

• Measurement graphs can be saved as “csv” formatted text files.


LTP with Mobius

Acquisition and stimulation parameters are set in the top control panel, and data acquired at all 64 channels is displayed on the bottom.

Single pulse stimulation is applied through channel 20 and 21 alternatively. The stimulus amplitude and waveform for channel 20 is programmed by the [Step1] while the one for channel 21 is programmed by [Step2].

Evoked Potential Measurement Package
View  Larger Image
Evoked Potential Measurement Package
View  Larger Image
Stimulation protocol for Step2


Display for analysis

Slope 10-40% (red) and Amplitude Minimum (blue) are selected here. (The specific analysis can be changed and/or added.)

The upper chart shows the result for the experimental pathway (Step 1stimulus at channel 20) while bottom chart shows the result for control pathway (Step 2 stimulus at channel 21).

Channel 29 is selected for on-line monitoring. Acquisition and analyses are performed at all 64 channels. The results for a specific channel can be displayed by selecting the channel at the bottom-left channel selector. The number of charts can be increased.

Evoked Potential Measurement Package
View  Larger Image
Evoked Potential Measurement Package
View  Larger Image
A stimulus protocol for conditioning stimulation for application after the baseline recording


Automatic Input/Output curve

The stimulus amplitude is automatically increased and input/output curve is obtained consequently.

Evoked Potential Measurement Package
View  Larger Image
A control panel for making I/O curve. The stimulus amplitude is automatically increased by 2 µA from a starting current of -10µA. (-10µA, -12µA, -14µA ------)

View  Larger Image
The Input / Output curve obtained automatically


 

MED64 Software

Evoked Potential Measurement Package


Spike Sorter Package


Mobius QT

Mobius QT

 
Download Brochure