AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

Siskiyou Economy Manual Translator Buy NowDownload Brochure
       
Siskiyou Electrode Holder

Electrode Holder

The new Stable-tip electrode holders eliminate the final instability link in the electrophysiology experimental setup. We’ve taken a thermally stable base material and coated it with aluminaoxide. This coating has two benefits: first, it is non-conductive so the holder does not act as an electrical antenna; second, it is very resistant to corrosion.

Under conditions of a high resistance electrode seal (gigaseal), the ST series electrode holder has a noise level of 0.79–0.80 pA RMS (5kHz filter); polycarbonate measured 0.78–0.79 pA (reported using an Axopatch 200B in whole-cell mode). The base material of the Stable-tip has a thermal expansion coefficient of 23μm/m°C versus 70μm/m°C of a polycarbonate holder. That is an improvement by a factor of three.

The Stable-tip electrode holders come with one (1) each of Ag-wires and wire seals.

NOTE: Pipette seals are not required for the latest model ST-50. When ordering, specify the headstage amplifier. If ordering for a Axon CV-4 the major diameter of the mounting feature is needed.


Siskiyou Economy Manual Translator


Model
Description
ST50-200/HS
Fits Axon 200/700 & HS-2A amplifiers
ST50-BNC
Fits amplifiers with BNC connectors
ST50-CV
Fits Axon CV-4 amplifiers


Specifications

• High thermal stability

• Low noise

• Versions for BNC and threaded headstage attachment

• Thermal expansion coefficient, CTE linear 68°:
Polycarbonate 70 μm/m-°C
Stable-tip 23 μm/m-°C

•  Electronic noise characteristics:
Polycarbonate 0.78–0.79 pA
Stable-tip 0.79–0.80 pA

 