AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

Delta T® Open Dish Systems Buy NowDownload BrochureDownload Brochure
       
Delta T® Open Dish Systems

Bioptechs Delta T® Controlled Culture Dish System

Finally a culture dish system specifically designed for live-cell microscopy! Now you can have accurate temperature control and high-numeric aperture compatibility in a convenient disposable culture dish system that even works in confocal applications.

• Easily adapted to a variety of specimen types from monolayered adherent cells to brain slice and tissue preps

• Low mass to thermo-regulate as opposed to conventional stage heaters

• Plate, incubate and observe without the need to transfer your cells

• Fast thermal recovery after perfusion (within seconds)

• Compatible with inverted and upright microscope stands

• Coverglass bottom for optimum optical compatibility

• No need for warm air blowers or stage heaters

• Direct first-surface heating to your cells

•  Can also be cooled below ambient

•  Perfusion available

•  No pre-heating

Bioptechs is now introducing the next generation Open Culture Dish Micro-Environmental Control System: the Delta T4. In addition to the improvements to the popular Delta TC3 control algorithm, Bioptechs has incorporated years of customer requests into the Delta T4. Click here for a description of optional features.

The Bioptechs, Inc. Delta T Culture Dish System is designed to simulate host conditions on the stage of your microscope and provide an optimal optical environment for microscopy. This two-step system allows you to plate your cells and observe them without having to transfer them to another structure. The system components are, the Controller, Stage Adapter, and Dishes. Accessories for Tissue Slice, Brain Slice, and other specimens are available.

An intelligent feedback loop passes an electrical current through a thin film coating on the underside surface of the glass substrate on which the cells are grown. Heat is applied directly to the cells without the inefficiencies associated with peripheral heating by traditional culture dish warmers. Bioptechs exclusively offers opaque culture dishes which eliminates the unwanted ambient light background for fluorescence imaging.

The controller features a real-time temperature display and fast learning curve to compensate for cooling due to surface evaporation while responding to temperature changes due to perfusion. There is also an alarmed protection circuit to safeguard the cells and an internal reference for the user adjustable calibration. The standard controller has a temperature range of ambient to 50 degrees C. Extended ranges are available upon request.

Delta T dishes have 35mm O.D. and a 23mm central aperture. The peripheral region of the dish is tapered to reduce the dead-volume and the height of the dish is 6mm to allow better access for micro-injection and micromanipulation. The dishes are a hybrid of polystyrene plastic and Desag 263 glass. The outer structure of the dish is available in opaque black or clear and come with a clear 0.5mm or no.1.5 glass coverslip bottom bonded to it. The dishes are also available in a plain glass unheated version.

Delta T


Delta T

• Easier technique

• Accurate temperature control

• Low dead volume

• Fast recovery

• Superior optical image

Traditional Stage Heater


Traditional Stage Heater


• Heating stages systems are not efficient

• Plastic dishes are a poor conductor of heat

• Temperature does not recover quickly during or after perfusion

• Plastic bottomed dishes are not suitable for high resolution microscopy

• Non-uniform temperature distribution

• Unnecessary dead volume


Low numeric aperture users need only purchase the basic Delta T with .5mm dishes. However if you are using high numeric aperture objectives (immersion) you will need the .15mm dishes. It will be necessary to regulate the temperature of the objective as well. In this case a Bioptechs, Inc. Objective Heater and an Objective Heater Controller will be necessary for uniform temperature across the field. Once you become familiar with its operation, you will find the Delta T an indispensable addition to your scope.

Notes:

Click here to download an assembly and demonstrational video of the Delta T. (34 MB)

Click here download a PDF about Traditional Stage Warming with thermal images. (340 K)

To assist you and Bioptechs in selecting the most appropriate system to meet your needs, please download and fill out a PDF of Micro-Environmental System Profile Questions (36 K)
Buy NowDownload BrochureDownload Brochure

Top Home Credits Privacy Terms Copyright

©2006-2016 AutoMate Scientific, Inc.