AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

FCS2 Closed Chamber-Inverted Buy NowDownload BrochureDownload Brochure
       
FCS2 Closed Chamber-Inverted

FCS2 Closed Chamber-Inverted

After rigorous preparation your cells will need a micro-observation environment that is conducive to their viability, compatible with your experiments protocol and all techniques of microscopy!

What is it?

The Focht Chamber System 2 (FCS2 ®) is a closed system, live-cell micro-observation chamber, that offers several advantages over other chambers. In addition to its unique perfusion and thermal control systems it is fully compatible with all modes of microscopy. It is also the only chamber to combine high-volume laminar flow perfusion rates with Koehler illumination and precise temperature control without an air curtain.

The system is comprised of:

• Chamber (environmental optical cavity, this page)

• Electronic Controller (this page)

• Stage Adapter

Accessories recommended for immersion objectives:

• Objective Heater

• Objective Temperature Controller

How does it work?

Temperature Control

The FCS2 was designed to maintain accurate thermal control and allow high-volume laminar flow perfusion. Both of these functions are incorporated into our patented Microaqueduct Slide. The surface of the slide, opposite the specimen side, is coated with an electrically conductive transparent thin film of Indium-Tin Oxide (ITO) and two electrical contacts (busbars). When the FCS2 is completely assembled two electrical contacts, (not shown in drawing), which are contained in the electrical enclosure rest on the busbars. A temperature controller is used to pass a regulated current flow through the ITO Coating. This causes the surface of the slide to heat. The heat is transferred through the perfusable media to the cell surface on the coverslip thereby providing first surface thermal control. The self locking base of the chamber is also temperature regulated to provide peripheral heat as well.

Microaqueduct Perfusion

A fluid pathway is formed by separating the Microaqueduct slide from the coverslip containing cells with a single silicone gasket. This gasket can be any thickness from 50 micron to 1mm and any lateral geometry you choose or create. This arrangement allows the user to define the flow characteristics. Therefore, you are not limited by the geometry of the optical cavity instead you select or create it! Fluid access to this flow channel is made through two 14-gauge needle stock tubes protruding from the sides of the chamber top. These tubes provide fluid connection to two perfusion holes in the Microaqueduct slide that interface two "T" shaped grooves cut into the inner surface of the Microaqueduct slide. The “T” groove allows the media to seek the path of least resistance and become nearly laminar before flowing across the cells. This technique eliminates the need for the metal perfusion ring and additional gaskets, which are the limiting factors, required by most conventional chambers.

Microaqueduct design enables proper Koehler illumination with high-numeric aperture optics for both transmitted and reflected modes of microscopy.

• Suitable for no flow through high rate flow procedures where a rapid exchange of media is required with low cell surface shear

• Cell temperature can be controlled from ambient to 50 degrees C +/- 0.2 degrees C without the need of an air curtain

• Temperature is controlled uniformly across entire field with media equilibrating as it enters the chamber

•  Closed system so that bicarbonate CO2 or organic buffers can be employed

• Compatible with 1/16" tubing for perfusion (C-Flex, Tygon, etc.)

 Easily assembled with ordinary skill (no tools required)

• Stand-alone temperature controller with an alarm circuit to safeguard your cells

• Near laminar flow

FCS2


Isometric View of Optical Cavity

Microaqueduct Slide is transparent glass but rendered as a solid to improve contrast to illustrate function. This image is rendered upside down, to demonstrate how the
Optical Cavity works. In an FCS2 chamber the coverslip will be on the bottom.

FCS2

 

FCS2
Assembled FCS2


FCS2 Exploded View

 

FCS2

1 Electrical Enclosure (Can also be detached to sterilize the perfusion tubes) • Temperature sensor
• Heater contacts
2 Upper Half (Top) Contains the perfusion tubes
3 Perfusion Tubes (14 gauge)
4 Upper Gasket  
5 Microaqueduct Slide (An optical surface which integrates perfusion and temperature control)
• High-volume laminar flow
• Koehler Illumination
• Electronically conductive coating for temperature control
6 Singular lower gasket • This gasket can have any internal geometry you desire
• Standard thicknesses from .1mm to 1mm
• Allows you to define the volume and flow characteristics of the chamber
7 40mm coverslip  
8 Self locking base (Designed to assure parallel uniform closure, eliminate leaks, & broken coverslips)
• Temperature controlled
• Dovetail mounted to scope for stability
• No tools for assembly


Singular Lower Gasket


By simply changing this one gasket you can change the volume of the chamber. This gasket can have any internal geometry you desire and can be any thickness from .1mm to 1mm. The drawing below shows the standard shapes of the gaskets that we include with every FCS2. We also include solid gaskets for you to custom fit to your application. Once you have found the shape that works best for your experiment you can contact us to have a die made to those specifications. Examples of standard gasket outlines (below)

FCS2


The Gasket Set Includes:

(3) 0.1mm 30mm Round
(2) 0.1mm 14 x 24
(3) 0.25mm 30 mm Round
(2) 0.25mm 14 x 24
(1) 0.25mm Blank
(3) 0.5mm 30mm Round
(2) 0.5mm 14 x 24
(2) 0.5mm Blank
(5) 0.75mm 30mm Round w/holes
(2) 0.75mm 14 x 24
(1) 0.75mm Blank
(2) -1.0mm 30mm Round
(1) 1.0mm 14 x 24
(1) 1.0mm Blank

Custom shapes are available. Simply contact Bioptechs to make arrangements for their production.

Open Mode Top for the FCS2

The open mode option allows for the FCS2 to be assembled without the microaqueduct slide thus exposing the cell on the cover slip for microinjection. The coverslip can then be removed and reassembled with the microaqueduct slide for long term, time-lapse.

FCS2 FCS2
Open Mode Adapter Installed on FCS2 Base Open Mode Adapter Installed on FCS2 Base

 

FCS2 Specifications

Physical Size:
75mm OD 13mm high

Coverslip No:
1.5 thick x 40mm Diameter

Imaging Aperture:
22mm

Maximum Volume:
706mm^3

Minimum Volume:
<31mm^3

Maximum Volume Exchange Rate:
1/sec

Minimum Fluid Aperture:
0.6mm^2

Separation between optical surfaces: 50 - 1000 microns

External port ID:
1.6mm

Temperature Stability:
+/- 0.2 degrees C

Important Notes

If you are using immersion objectives on mammalian specimens, you will need an Objective Heater!

Click here to download an assembly and demonstrational video of the FCS2 (30 MB)

Click here to download a PDF of FCS2 user instructions (724 K)

Click here download a PDF about Traditional Stage Warming with thermal images. (340 K)

Click here to download a PDF about Typical FCS2 Perfusion Configuration For Induced Change Biology (724 K)

To assist you and Bioptechs in selecting the most appropriate system to meet your needs, please download and fill out a PDF of Micro-Environmental System Profile Questions (36 K)

Buy NowDownload BrochureDownload Brochure

Top Home Credits Privacy Terms Copyright

©2006-2016 AutoMate Scientific, Inc.