AutoMate Scientific - Ready For Research
OUR PRODUCTS
Perfusion Systems Perfusion Systems
Pressurized Superfusion Pressurized Superfusion
Temperature Control Temperature Control
SmartSquirt® Microperfusion
Perfusion Chambers Perfusion Chambers
Rodent Fixation Systems
Brain Slice and Tissue Chambers Brain Slice & Tissue Chambers
Customize a Perfusion System
Complete Electrophysiology Rig
Amplifiers and Stimulators Amplifiers & Stimulators
MDC/Axon Instruments Heka Data Acquisition
Heka Data Acquisition Heka Data Acquisition
Siskiyou Mechanicals Siskiyou Mechanicals
Sutter Manipulators Sutter Manipulators
Micropipette Fabrication Micropipette Fabrication
TMC Air Tables TMC Air Tables
MED64 Multi-Electrode Array Multi-electrode Array
Automated Pipette Patch Clamping Automated Patch Clamping
Port-a-Patch® Planar Patch Clamping
Vesicle Prep Pro Bilayer Apparatus
Filter Wheels Optical Instruments
Functionalized Bio-surfaces Functionalized Bio-surface
Main Products Page
Download a Catalog

Objective Sizing Page
Objective Heater Compatibility

Note: This is not a complete list of all objectives. If the Objective you need is not listed below, or if you have a photo of an objective not shown here, e-mail us with information or a photo of your Objective. Click here for instructions on how to size your objective.

Objective Manufacturer Specifications Size Heater

Leica

PL APO

100x/1.40 Oil/0.17/D

Large

Nikon

LWD

40x/0.55/Hoffman Modulation Contrast/0-2 WD 2.1

Standard

Nikon

Plan Fluor

100x/1.30 Oil/DIC H/0.17 WD 0.20

Standard

Nikon

Plan Fluor

100x/0.5-1.3 Oil Iris/DIC H/N2/0.17 WD 0.2

Large

Note:
Requires thermal isolator.

Nikon

Plan Fluor

40x/1.30 Oil/DIC H/0.17 WD 0.20

Medium

Nikon

Plan Apo N

60x/1.42 Oil /0.17 / FN26.5

Medium

Nikon

Plan Apo

100x/1.40 Oil/DIC H/0.17 WD 0.13

Standard

Nikon

Plan Apo

100x/1.40 Oil /0.17 / PH3 / DM

Medium

Nikon

Plan Apo

60x/1.20 WI/DIC H

Standard

Nikon

Plan Apo

60xA/1.40 Oil/DIC H/0.17 WD 0.21

Large

Nikon

Plan Apo

60xA/1.40 Oil/Ph3 DM/0.17 WD 0.21

Large

Nikon

Plan Apo VC

60x/1.40 Oil/0.17/DIC N2

Large
Nikon

Plan Apo TIRF

60x/1.45 Oil/0.10-0.22 WD 0.13

Medium

Nikon

Plan Apo TIRF

60x/1.45 Oil/0.10-0.22 DIC H

Medium

Nikon

40x

Know the exact specifications? email us

Standard
Nikon

60x

 Know the exact specifications? email us

Unknown

Olympus

Apo

100x 1.65 Oil/0.17

Unknown
Olympus

UPlanSApo

100x/1.40 Oil/0.17/FN26.5

Medium
Olympus

UPlanApo

60x/1.20W/0.13-0.21

Large

Note:
Suggested thermal isolator.

Olympus

UPlanApo

60x/1.20W PSF/0.13-0.21

Medium

Note:
Suggested thermal isolator.

Olympus

UPlanApo

100x/1.35 Oil/0.17

Standard

Note:
Requires thermal isolator.

Olympus

UApo

340/40x/1.35 Oil Iris

Large

Note:
Requires thermal isolator.

Olympus

UApo

340/40x/1.15W/0.13-0.25

Standard

Olympus

UApo

340/20x/0.70W/0.17

 

Standard

Note:
Requires thermal isolator.

Olympus

LUM PlanFI Ir

60x/0.90 W/0

None

Note:
Water dipping lenses do not require the use of an Objective Heater.

Olympus

XLUMPlan FI

20x/0.95 W/0

Medium

Note:
Water dipping lenses usually do not require the use of an Objective Heater. However, due to the large size of this objective and short length of the dipping sleeve, an Objective Heater is recommended.

Olympus

PlanApo

100x/1.40 Oil

Standard

Olympus

PlanApo

60x/1.40 Oil/0.17

Standard

Olympus

PlanApo N

60x/1.45 Oil/ 0.13-0.19/FN26.5

TIRFM UIS2 BFP1

Large

Olympus

UPlanFl

60x/1.25 Oil/ 0.17/FN26.5

Large

Olympus

UPlanFl

100x/1.30 Oil/0.17

Standard

Olympus

UPlanFL N

100x/1.30 Oil/ 0.17/FN26.5

Medium

Olympus

Hoffman Modulation Contrast HMC

40x/WD LCA/0.55n/INF/1

Standard

Olympus

Unkown

(1) Standard

(2) Standard

Olympus

LCPlanFl

40x/0.60 Ph2/

Standard

Zeiss

LD ACHROPLAN

40x/0.60 Korr Ph2/0-2

Large

Picture not available Zeiss

C-APROCHROMAT

40x/1.2 W Korr/0.15-0.17

Large
Zeiss

C-APROCHROMAT

63x/1.2 W Korr/0.15-0.17

Large

Zeiss

Plan-APOCHROMAT

63x/1.40 Oil

Standard

Zeiss

ACHROPLAN

63x/0.90 W/PH3

None

Note:
Water dipping lenses do not require the use of an objective heater.

Zeiss

ACHROPLAN

100x/1.25 Oil/0.17

Standard

 

How to Size Your Objective

(A) = The diameter of the spring loaded retractable portion of the objective. This is the diameter that the heater band must fit.
(B) = The minimum vertical surface needed to mount the Objective Heater and transfer heat.

Microscope ObjectiveObjective Heater (Top View)Objective Heater (Side View)

 

Bioptechs Objective Heater Band Sizes

Standard Medium Large
(A) 17-28 mm (A) 21-30 mm (A) 30-38mm
(B) 5.5 mm (B) 5.5 mm (B) 3.5 mm

Note: The above diagram depicts a typical Objective Heater mounting location. There are a wide variety of objective configurations. It may be necessary to mount an Objective Heater at a different location than indicated above. Some objectives require the removal of a decorative collar (below, top). If removal of the decorative collar is required, an objective wrench and pliers (below, bottom) are available.

 

Information and color explanations on Objectives from Zeiss

Label Example

# Explanation Color / Explanation
(1) The lettering color characterizes the objective type and the contrast method intended for the objective. Black: Standard (plus DIC in some types)
Red: Low-strain for polarization / DIC
Green: Phase 1, 2, 3
(2) Magnification / numerical aperture  
(3) Tube length / cover glass thickness. Tube length "infinite" marks ICS optics  
(4) Magnification color coding —— Black: 1,25x
—— Brown: 2,5x
—— Red: 4x, 5x
—— Orange: 6,3x
—— Yellow: 10x
—— Green: 16x, 20x, 25x, 32
—— Light Blue: 40x, 50x
—— Dark Blue: 63x
—— White: 100x, 150x
(5) Function element (knurled collar)

•  For optical correction with various immersion media or differing cover glass / vessel bottom thicknesses or
•  On objectives with variable aperture iris
 
(6) Color coding for the immersion liquid to be used —— Black: oil
—— White: water
—— Orange: glycerol
—— Red: variable

 

 
 
Top Home Credits Privacy Terms Copyright