Pipette Holders

HL-U: Connects to all U-type headstages

Electrode holder for all Axon headstages, 1.0-1.7 mm glass
HL-U Diagram

How to know which pipette holder you need:

  • Is the collar (where the holder attaches to the headstage) threaded or smooth?
  • If it is threaded, then you need the HL-U (most common).
  • If it does NOT have threads, then Molecular Devices no longer makes electrode holders for you.

For use only with threaded headstage collets.

HL-U For 1.0-1.7 mm glass

$270.00Add to cart

HLB-U BNC adapter

$133.00Add to cart

HLR-U Right-angle adapter

$327.00Add to cart

Four different sizes of cone washers allow the holder to accommodate pipettes with outer diameters from 1.0 to 1.7 mm. Suction port connects to 1 mm ID tubing. Low-noise easy-maintenance construction. Contains a 0.25 mm silver wire. Spare components supplied are as follows: cone washers (five of each size), four 50 mm lengths of silver wire and 70 mm of silicone tubing to make new seals. BNC adapter accepts a BNC-type electrode holder.

HLR-U

Replacement Parts for HL-U Holder

Replacement-Gaskets

HL-CAP Two polycarbonate caps

$80.00Add to cart

HLC-11 Orange cone washer (pack of 5), 1.1 mm ID, fits 1.0 – 1.1 mm OD glass

$44.00Add to cart

HLC-13 Clear cone washer (pack of 5), 1.3 mm ID, fits 1.1 – 1.3 mm OD glass

$44.00Add to cart

HLC-15 Orange cone washer (pack of 5), 1.5 mm ID, fits 1.3 – 1.5 mm OD glass

$44.00Add to cart

HLC-17 Clear cone washer (pack of 5), 1.7 mm ID, fits 1.5 – 1.7 mm OD glass

$44.00Add to cart

HLP-U Brass pins, 1 mm, pack of 3 for HL-U electrode holders

$54.00Add to cart

HLT-70  Silicone tubing, 1 mm ID, 70 mm long

$35.00Add to cart

HL-1 and HL-2: Connect to non-U-type CV Series headstages

HLR-2

For use only with non-threaded white PTFE inert collets.

HLB-1 BNC adapter – Ask

HLR-1 Right-angle adapter – Ask|

HL-2-17 For 1.5-1.7 mm glass

$230.00Add to cart

Important Notes

  • We are now only selling the ‘U-type’ headstages with the threaded white PTFE inert collets, which connect only to HL-U holders, or U-type adapters and model cells.
  • All adapters and holders must be ordered separately.

Ag/AgCl pellets and Ag wires

For All U-type and Non-U-type Holders

HLA-003 Ag/AgCl pellet assemblies, pack of 3 1 mm diameter AgCl pellet on the end of an Ag wire. The Ag wire is insulated from the electrode solution by a wax-sealed PTFE inert tube.

$265.00Add to cart

HLA-005 Ag wires, pack of 5
Ag wires used in all holders. The 0.25 mm wires are 50 mm long.

$44.00Add to cart

Replacement Parts for HL-1 and HL-2 Holders

HLO-12 ‘O’ rings fit HL-1-12 and HL-2-12 holders,
pack of 10 – Ask

HLO-17 ‘O’ rings fit HL-1-17 and HL-2-17 holders,
pack of 10

$68.00Add to cart

HLP-O general purpose 2 mm plugs,
pack of 5

$44.00Add to cart

HLP-1 1 mm brass pins for HL-1 holders,
pack of 3

$44.00Add to cart

HLP-2 2 mm brass pins for HL-2 holders,
pack of 3

$44.00Add to cart

HLS-001 pierced rubber seals fit HL-1 and HL-2 holders,
pack of 10

$68.00Add to cart